{"id":73990,"date":"2026-08-05T11:10:19","date_gmt":"2026-08-05T16:10:19","guid":{"rendered":"https:\/\/colombiainteligente.org\/?p=73990"},"modified":"2026-08-05T11:12:05","modified_gmt":"2026-08-05T16:12:05","slug":"developing-sustainable-system-for-future-data-centers","status":"publish","type":"post","link":"https:\/\/colombiainteligente.org\/es_co\/tendencias\/developing-sustainable-system-for-future-data-centers\/","title":{"rendered":"Developing Sustainable System for Future Data Centers"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"73990\" class=\"elementor elementor-73990\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-87c6aa2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"87c6aa2\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-558bb819\" data-id=\"558bb819\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3067325c elementor-widget elementor-widget-text-editor\" data-id=\"3067325c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.14.0 - 26-06-2023 *\/\n.elementor-widget-text-editor.elementor-drop-cap-view-stacked .elementor-drop-cap{background-color:#69727d;color:#fff}.elementor-widget-text-editor.elementor-drop-cap-view-framed .elementor-drop-cap{color:#69727d;border:3px solid;background-color:transparent}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap{margin-top:8px}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap-letter{width:1em;height:1em}.elementor-widget-text-editor .elementor-drop-cap{float:left;text-align:center;line-height:1;font-size:50px}.elementor-widget-text-editor .elementor-drop-cap-letter{display:inline-block}<\/style>\t\t\t\t<p style=\"margin-top: 5pt; margin-bottom: 5pt; font-family: Calibri; font-size: 11.0pt;\">El crecimiento acelerado de los centros de datos ha incrementado significativamente la demanda mundial de electricidad y las emisiones asociadas a su operaci\u00f3n, impulsado por la expansi\u00f3n de servicios digitales como la computaci\u00f3n en la nube, el almacenamiento masivo de informaci\u00f3n, la inteligencia artificial y las plataformas de transmisi\u00f3n de contenidos. Este escenario plantea la necesidad de replantear los esquemas tradicionales de suministro energ\u00e9tico, hist\u00f3ricamente sustentados en la red el\u00e9ctrica y generadores di\u00e9sel de respaldo, debido a sus elevados niveles de p\u00e9rdidas energ\u00e9ticas, emisiones de carbono y dependencia de combustibles f\u00f3siles. Bajo este contexto, el desarrollo de infraestructuras digitales sostenibles requiere complementar las estrategias de eficiencia energ\u00e9tica orientadas a reducir el consumo con enfoques que transformen tambi\u00e9n las fuentes de abastecimiento el\u00e9ctrico. La transici\u00f3n hacia modelos energ\u00e9ticos de menor impacto ambiental adquiere mayor importancia en regiones donde las condiciones clim\u00e1ticas limitan el aprovechamiento de recursos renovables como la energ\u00eda solar y e\u00f3lica, obligando a explorar alternativas capaces de garantizar confiabilidad operativa, continuidad del servicio y reducci\u00f3n de emisiones sin comprometer el desempe\u00f1o de instalaciones que operan de forma ininterrumpida.<\/p><p style=\"margin-top: 5pt; margin-bottom: 5pt; font-family: Calibri; font-size: 11.0pt;\">A partir de estas condiciones, se eval\u00faan cuatro configuraciones energ\u00e9ticas para un centro de datos hipot\u00e9tico de 5 MW ubicado en la regi\u00f3n del Golfo, donde la disponibilidad de gas natural y la cercan\u00eda de la red el\u00e9ctrica ofrecen alternativas diferentes al aprovechamiento directo de fuentes renovables intermitentes. La comparaci\u00f3n considera un modelo convencional basado en la red el\u00e9ctrica y generadores di\u00e9sel, junto con tres configuraciones h\u00edbridas que incorporan celdas de combustible de \u00f3xido s\u00f3lido (SOFC), microturbinas de gas (MGT) y celdas de combustible de membrana de intercambio de protones (PEMFC). Cada propuesta analiza la combinaci\u00f3n de estas tecnolog\u00edas como fuente principal, respaldo secundario o suministro de emergencia, considerando aspectos relacionados con capacidad instalada, tiempos de respuesta, eficiencia energ\u00e9tica, requerimientos de espacio y emisiones de di\u00f3xido de carbono. Paralelamente, el an\u00e1lisis incorpora el indicador Power Usage Effectiveness (PUE), ampliamente utilizado para medir la eficiencia de los centros de datos mediante la relaci\u00f3n entre el consumo energ\u00e9tico total y la energ\u00eda utilizada directamente por los equipos inform\u00e1ticos. Reducir este indicador implica disminuir las p\u00e9rdidas asociadas a sistemas auxiliares, mejorar el aprovechamiento de la energ\u00eda suministrada y optimizar el funcionamiento integral de la instalaci\u00f3n. Asimismo, el estudio incorpora principios de econom\u00eda circular mediante el aprovechamiento del calor residual generado por las celdas SOFC para alimentar la microturbina de gas, incrementando la eficiencia global del sistema y reduciendo el desperdicio energ\u00e9tico.<\/p><p style=\"margin-top: 5pt; margin-bottom: 5pt; font-family: Calibri; font-size: 11.0pt;\">Posteriormente, la comparaci\u00f3n t\u00e9cnica evidencia diferencias importantes entre las alternativas analizadas. El sistema convencional presenta una confiabilidad dependiente del desempe\u00f1o de la red el\u00e9ctrica y registra p\u00e9rdidas energ\u00e9ticas cercanas al 66 %, resultado de las ineficiencias acumuladas durante la generaci\u00f3n centralizada, la transmisi\u00f3n, la distribuci\u00f3n y los equipos internos de conversi\u00f3n el\u00e9ctrica. En contraste, los modelos basados en generaci\u00f3n distribuida mediante SOFC-MGT reducen las p\u00e9rdidas hasta aproximadamente el 42 %, gracias a una eficiencia global cercana al 65 % y a la eliminaci\u00f3n de diversos equipos de conversi\u00f3n presentes en los dise\u00f1os tradicionales. Sin embargo, las configuraciones que dependen exclusivamente del suministro de gas natural o de un \u00fanico sistema de respaldo presentan limitaciones frente a fallas de combustible, mantenimientos programados o indisponibilidad de alguno de sus componentes. Bajo estas condiciones, la configuraci\u00f3n integrada por SOFC-MGT como fuente principal, la red el\u00e9ctrica como respaldo secundario y PEMFC como respaldo de emergencia ofrece el mayor nivel de confiabilidad al disponer de tres niveles independientes de suministro capaces de mantener la continuidad operativa incluso durante mantenimientos o contingencias simult\u00e1neas.<\/p><p style=\"margin-top: 5pt; margin-bottom: 5pt; font-family: Calibri; font-size: 11.0pt;\">La evaluaci\u00f3n ambiental confirma que la transformaci\u00f3n del esquema energ\u00e9tico tambi\u00e9n genera reducciones significativas en la huella de carbono de los centros de datos. Mientras el modelo convencional produce aproximadamente 23.004 toneladas equivalentes de di\u00f3xido de carbono, las configuraciones h\u00edbridas disminuyen estas emisiones alrededor de un 66 %, manteniendo diferencias relativamente peque\u00f1as entre ellas. Adem\u00e1s de reducir las emisiones, el modelo m\u00e1s completo ofrece ventajas operativas adicionales, como la posibilidad de intercambiar energ\u00eda con la red, realizar estrategias de reducci\u00f3n de demanda durante horas pico, evitar el sobredimensionamiento de equipos de generaci\u00f3n y extender la vida \u00fatil de los sistemas mediante una utilizaci\u00f3n m\u00e1s equilibrada de las distintas fuentes disponibles. De esta manera, la integraci\u00f3n de celdas de combustible, microturbinas de gas y sistemas de respaldo diversificados constituye una alternativa para avanzar hacia centros de datos con mayor eficiencia energ\u00e9tica, menores p\u00e9rdidas el\u00e9ctricas, menor impacto ambiental y mejores condiciones de confiabilidad, respondiendo al crecimiento sostenido de la infraestructura digital mediante soluciones compatibles con los objetivos globales de descarbonizaci\u00f3n y sostenibilidad.<\/p><p align=\"justify\"><span style=\"color: #800000;\"><b>Para leer m\u00e1s ingrese a:<\/b><\/span><\/p><p style=\"margin: 0in; font-family: Calibri; font-size: 11.0pt;\"><a href=\"https:\/\/cse.cigre.org\/cse-n041\/developing-sustainable-system-for-future-data-centers.html\">https:\/\/cse.cigre.org\/cse-n041\/developing-sustainable-system-for-future-data-centers.html <\/a><\/p><p style=\"margin: 0in; font-family: Calibri; font-size: 11.0pt;\"><a href=\"https:\/\/cse.cigre.org\/cse-n041\/developing-sustainable-system-for-future-data-centers.pdf?tx_site_pdfdownload%5BaccessToken%5D=dummyToken&amp;tx_site_pdfdownload%5Baction%5D=download&amp;tx_site_pdfdownload%5Bcontroller%5D=Pdf&amp;tx_site_pdfdownload%5BpdfProject%5D=11835&amp;cHash=81ab5db615796f2c4f03e992ff51e6f6\">https:\/\/cse.cigre.org\/cse-n041\/developing-sustainable-system-for-future-data-centers.pdf<\/a><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t\t\t<\/div>\n\t\t<div style=\"text-align:center\" class=\"yasr-auto-insert-visitor\"><\/div>","protected":false},"excerpt":{"rendered":"<p>El crecimiento de los centros de datos ha incrementado el consumo energ\u00e9tico y las emisiones de carbono, impulsando la b\u00fasqueda de alternativas que permitan mantener la confiabilidad operativa mientras se reduce el impacto ambiental. Para responder a este desaf\u00edo, se comparan cuatro configuraciones energ\u00e9ticas para un centro de datos de 5 MW, incluyendo un modelo convencional basado en la red el\u00e9ctrica y generadores di\u00e9sel, adem\u00e1s de tres configuraciones h\u00edbridas que integran celdas de combustible de \u00f3xido s\u00f3lido, microturbinas de gas y celdas de combustible de membrana de intercambio de protones. La evaluaci\u00f3n considera criterios de confiabilidad, p\u00e9rdidas energ\u00e9ticas y emisiones de di\u00f3xido de carbono. Los resultados muestran que los modelos con generaci\u00f3n distribuida disminuyen las p\u00e9rdidas el\u00e9ctricas desde aproximadamente 66 % hasta 42 %, gracias a una mayor eficiencia y a la reducci\u00f3n de etapas de conversi\u00f3n el\u00e9ctrica. Asimismo, el aprovechamiento del calor residual mediante principios de econom\u00eda circular incrementa el rendimiento global del sistema. Desde la perspectiva ambiental, las configuraciones h\u00edbridas reducen alrededor del 66 % de las emisiones respecto al esquema convencional. Entre las alternativas evaluadas, el modelo que combina generaci\u00f3n mediante SOFC-MGT, respaldo de la red el\u00e9ctrica y PEMFC como suministro de emergencia presenta el mejor equilibrio entre confiabilidad, eficiencia energ\u00e9tica, flexibilidad operativa y descarbonizaci\u00f3n, constituyendo una alternativa sostenible para futuras infraestructuras digitales de alta disponibilidad.<\/p>","protected":false},"author":23,"featured_media":73991,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"yasr_overall_rating":0,"yasr_post_is_review":"","yasr_auto_insert_disabled":"","yasr_review_type":"","footnotes":""},"categories":[54,53],"tags":[],"class_list":["post-73990","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-energia-que-transforma","category-tendencias"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Developing Sustainable System for Future Data Centers - Colombia Inteligente<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/colombiainteligente.org\/es_co\/tendencias\/developing-sustainable-system-for-future-data-centers\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Developing Sustainable System for Future Data Centers - Colombia Inteligente\" \/>\n<meta property=\"og:description\" content=\"El crecimiento de los centros de datos ha incrementado el consumo energ\u00e9tico y las emisiones de carbono, impulsando la b\u00fasqueda de alternativas que permitan mantener la confiabilidad operativa mientras se reduce el impacto ambiental. Para responder a este desaf\u00edo, se comparan cuatro configuraciones energ\u00e9ticas para un centro de datos de 5 MW, incluyendo un modelo convencional basado en la red el\u00e9ctrica y generadores di\u00e9sel, adem\u00e1s de tres configuraciones h\u00edbridas que integran celdas de combustible de \u00f3xido s\u00f3lido, microturbinas de gas y celdas de combustible de membrana de intercambio de protones. La evaluaci\u00f3n considera criterios de confiabilidad, p\u00e9rdidas energ\u00e9ticas y emisiones de di\u00f3xido de carbono. Los resultados muestran que los modelos con generaci\u00f3n distribuida disminuyen las p\u00e9rdidas el\u00e9ctricas desde aproximadamente 66 % hasta 42 %, gracias a una mayor eficiencia y a la reducci\u00f3n de etapas de conversi\u00f3n el\u00e9ctrica. Asimismo, el aprovechamiento del calor residual mediante principios de econom\u00eda circular incrementa el rendimiento global del sistema. Desde la perspectiva ambiental, las configuraciones h\u00edbridas reducen alrededor del 66 % de las emisiones respecto al esquema convencional. Entre las alternativas evaluadas, el modelo que combina generaci\u00f3n mediante SOFC-MGT, respaldo de la red el\u00e9ctrica y PEMFC como suministro de emergencia presenta el mejor equilibrio entre confiabilidad, eficiencia energ\u00e9tica, flexibilidad operativa y descarbonizaci\u00f3n, constituyendo una alternativa sostenible para futuras infraestructuras digitales de alta disponibilidad.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/colombiainteligente.org\/es_co\/tendencias\/developing-sustainable-system-for-future-data-centers\/\" \/>\n<meta property=\"og:site_name\" content=\"Colombia Inteligente\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-05T16:10:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-05T16:12:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/colombiainteligente.org\/wp-content\/uploads\/2026\/08\/05-Energia-4660826.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1332\" \/>\n\t<meta property=\"og:image:height\" content=\"1872\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"DIFUSI\u00d3N COLOMBIA INTELIGENTE\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@colombiaintelig\" \/>\n<meta name=\"twitter:site\" content=\"@colombiaintelig\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"DIFUSI\u00d3N COLOMBIA INTELIGENTE\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo estimado de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/\"},\"author\":{\"name\":\"DIFUSI\u00d3N COLOMBIA INTELIGENTE\",\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/#\\\/schema\\\/person\\\/e207145d548b75a6d339ff1d4d3b0432\"},\"headline\":\"Developing Sustainable System for Future Data Centers\",\"datePublished\":\"2026-08-05T16:10:19+00:00\",\"dateModified\":\"2026-08-05T16:12:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/\"},\"wordCount\":856,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/colombiainteligente.org\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/05-Energia-4660826.webp\",\"articleSection\":[\"Energ\u00eda que transforma\",\"Tendencias\"],\"inLanguage\":\"es-CO\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/\",\"url\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/\",\"name\":\"Developing Sustainable System for Future Data Centers - Colombia Inteligente\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/colombiainteligente.org\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/05-Energia-4660826.webp\",\"datePublished\":\"2026-08-05T16:10:19+00:00\",\"dateModified\":\"2026-08-05T16:12:05+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/#breadcrumb\"},\"inLanguage\":\"es-CO\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es-CO\",\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/colombiainteligente.org\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/05-Energia-4660826.webp\",\"contentUrl\":\"https:\\\/\\\/colombiainteligente.org\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/05-Energia-4660826.webp\",\"width\":1332,\"height\":1872},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/tendencias\\\/developing-sustainable-system-for-future-data-centers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/colombiainteligente.org\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Developing Sustainable System for Future Data Centers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/#website\",\"url\":\"https:\\\/\\\/colombiainteligente.org\\\/\",\"name\":\"Colombia Inteligente\",\"description\":\"Alianza estrat\u00e9gica, conformada por empresas y entidades, para la inserci\u00f3n integral y eficiente de las redes inteligentes a la infraestructura del sector el\u00e9ctrico colombiano\",\"publisher\":{\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/colombiainteligente.org\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es-CO\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/#organization\",\"name\":\"Colombia Inteligente\",\"url\":\"https:\\\/\\\/colombiainteligente.org\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-CO\",\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/colombiainteligente.org\\\/wp-content\\\/uploads\\\/2022\\\/07\\\/Image.png\",\"contentUrl\":\"https:\\\/\\\/colombiainteligente.org\\\/wp-content\\\/uploads\\\/2022\\\/07\\\/Image.png\",\"width\":588,\"height\":274,\"caption\":\"Colombia Inteligente\"},\"image\":{\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/colombiaintelig\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/colombiainteligente\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/colombiainteligente.org\\\/#\\\/schema\\\/person\\\/e207145d548b75a6d339ff1d4d3b0432\",\"name\":\"DIFUSI\u00d3N COLOMBIA INTELIGENTE\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-CO\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/df2e679ff2abf288cf4bf58830dad897e596908105ec8969f50f748a6d837869?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/df2e679ff2abf288cf4bf58830dad897e596908105ec8969f50f748a6d837869?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/df2e679ff2abf288cf4bf58830dad897e596908105ec8969f50f748a6d837869?s=96&d=mm&r=g\",\"caption\":\"DIFUSI\u00d3N COLOMBIA INTELIGENTE\"},\"url\":\"https:\\\/\\\/colombiainteligente.org\\\/es_co\\\/author\\\/difusioncolombiainteligente-org\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Developing Sustainable System for Future Data Centers - Colombia Inteligente","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/colombiainteligente.org\/es_co\/tendencias\/developing-sustainable-system-for-future-data-centers\/","og_locale":"es_ES","og_type":"article","og_title":"Developing Sustainable System for Future Data Centers - Colombia Inteligente","og_description":"El crecimiento de los centros de datos ha incrementado el consumo energ\u00e9tico y las emisiones de carbono, impulsando la b\u00fasqueda de alternativas que permitan mantener la confiabilidad operativa mientras se reduce el impacto ambiental. Para responder a este desaf\u00edo, se comparan cuatro configuraciones energ\u00e9ticas para un centro de datos de 5 MW, incluyendo un modelo convencional basado en la red el\u00e9ctrica y generadores di\u00e9sel, adem\u00e1s de tres configuraciones h\u00edbridas que integran celdas de combustible de \u00f3xido s\u00f3lido, microturbinas de gas y celdas de combustible de membrana de intercambio de protones. La evaluaci\u00f3n considera criterios de confiabilidad, p\u00e9rdidas energ\u00e9ticas y emisiones de di\u00f3xido de carbono. Los resultados muestran que los modelos con generaci\u00f3n distribuida disminuyen las p\u00e9rdidas el\u00e9ctricas desde aproximadamente 66 % hasta 42 %, gracias a una mayor eficiencia y a la reducci\u00f3n de etapas de conversi\u00f3n el\u00e9ctrica. Asimismo, el aprovechamiento del calor residual mediante principios de econom\u00eda circular incrementa el rendimiento global del sistema. Desde la perspectiva ambiental, las configuraciones h\u00edbridas reducen alrededor del 66 % de las emisiones respecto al esquema convencional. Entre las alternativas evaluadas, el modelo que combina generaci\u00f3n mediante SOFC-MGT, respaldo de la red el\u00e9ctrica y PEMFC como suministro de emergencia presenta el mejor equilibrio entre confiabilidad, eficiencia energ\u00e9tica, flexibilidad operativa y descarbonizaci\u00f3n, constituyendo una alternativa sostenible para futuras infraestructuras digitales de alta disponibilidad.","og_url":"https:\/\/colombiainteligente.org\/es_co\/tendencias\/developing-sustainable-system-for-future-data-centers\/","og_site_name":"Colombia Inteligente","article_published_time":"2026-08-05T16:10:19+00:00","article_modified_time":"2026-08-05T16:12:05+00:00","og_image":[{"width":1332,"height":1872,"url":"https:\/\/colombiainteligente.org\/wp-content\/uploads\/2026\/08\/05-Energia-4660826.webp","type":"image\/webp"}],"author":"DIFUSI\u00d3N COLOMBIA INTELIGENTE","twitter_card":"summary_large_image","twitter_creator":"@colombiaintelig","twitter_site":"@colombiaintelig","twitter_misc":{"Escrito por":"DIFUSI\u00d3N COLOMBIA INTELIGENTE","Tiempo estimado de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/#article","isPartOf":{"@id":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/"},"author":{"name":"DIFUSI\u00d3N COLOMBIA INTELIGENTE","@id":"https:\/\/colombiainteligente.org\/#\/schema\/person\/e207145d548b75a6d339ff1d4d3b0432"},"headline":"Developing Sustainable System for Future Data Centers","datePublished":"2026-08-05T16:10:19+00:00","dateModified":"2026-08-05T16:12:05+00:00","mainEntityOfPage":{"@id":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/"},"wordCount":856,"commentCount":0,"publisher":{"@id":"https:\/\/colombiainteligente.org\/#organization"},"image":{"@id":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/#primaryimage"},"thumbnailUrl":"https:\/\/colombiainteligente.org\/wp-content\/uploads\/2026\/08\/05-Energia-4660826.webp","articleSection":["Energ\u00eda que transforma","Tendencias"],"inLanguage":"es-CO","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/","url":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/","name":"Developing Sustainable System for Future Data Centers - Colombia Inteligente","isPartOf":{"@id":"https:\/\/colombiainteligente.org\/#website"},"primaryImageOfPage":{"@id":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/#primaryimage"},"image":{"@id":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/#primaryimage"},"thumbnailUrl":"https:\/\/colombiainteligente.org\/wp-content\/uploads\/2026\/08\/05-Energia-4660826.webp","datePublished":"2026-08-05T16:10:19+00:00","dateModified":"2026-08-05T16:12:05+00:00","breadcrumb":{"@id":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/#breadcrumb"},"inLanguage":"es-CO","potentialAction":[{"@type":"ReadAction","target":["https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/"]}]},{"@type":"ImageObject","inLanguage":"es-CO","@id":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/#primaryimage","url":"https:\/\/colombiainteligente.org\/wp-content\/uploads\/2026\/08\/05-Energia-4660826.webp","contentUrl":"https:\/\/colombiainteligente.org\/wp-content\/uploads\/2026\/08\/05-Energia-4660826.webp","width":1332,"height":1872},{"@type":"BreadcrumbList","@id":"https:\/\/colombiainteligente.org\/tendencias\/developing-sustainable-system-for-future-data-centers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/colombiainteligente.org\/"},{"@type":"ListItem","position":2,"name":"Developing Sustainable System for Future Data Centers"}]},{"@type":"WebSite","@id":"https:\/\/colombiainteligente.org\/#website","url":"https:\/\/colombiainteligente.org\/","name":"Colombia Inteligente","description":"Alianza estrat\u00e9gica, conformada por empresas y entidades, para la inserci\u00f3n integral y eficiente de las redes inteligentes a la infraestructura del sector el\u00e9ctrico colombiano","publisher":{"@id":"https:\/\/colombiainteligente.org\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/colombiainteligente.org\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es-CO"},{"@type":"Organization","@id":"https:\/\/colombiainteligente.org\/#organization","name":"Colombia Inteligente","url":"https:\/\/colombiainteligente.org\/","logo":{"@type":"ImageObject","inLanguage":"es-CO","@id":"https:\/\/colombiainteligente.org\/#\/schema\/logo\/image\/","url":"https:\/\/colombiainteligente.org\/wp-content\/uploads\/2022\/07\/Image.png","contentUrl":"https:\/\/colombiainteligente.org\/wp-content\/uploads\/2022\/07\/Image.png","width":588,"height":274,"caption":"Colombia Inteligente"},"image":{"@id":"https:\/\/colombiainteligente.org\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/colombiaintelig","https:\/\/www.linkedin.com\/company\/colombiainteligente\/"]},{"@type":"Person","@id":"https:\/\/colombiainteligente.org\/#\/schema\/person\/e207145d548b75a6d339ff1d4d3b0432","name":"DIFUSI\u00d3N COLOMBIA INTELIGENTE","image":{"@type":"ImageObject","inLanguage":"es-CO","@id":"https:\/\/secure.gravatar.com\/avatar\/df2e679ff2abf288cf4bf58830dad897e596908105ec8969f50f748a6d837869?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/df2e679ff2abf288cf4bf58830dad897e596908105ec8969f50f748a6d837869?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/df2e679ff2abf288cf4bf58830dad897e596908105ec8969f50f748a6d837869?s=96&d=mm&r=g","caption":"DIFUSI\u00d3N COLOMBIA INTELIGENTE"},"url":"https:\/\/colombiainteligente.org\/es_co\/author\/difusioncolombiainteligente-org\/"}]}},"yasr_visitor_votes":{"number_of_votes":0,"sum_votes":0,"stars_attributes":{"read_only":false,"span_bottom":false}},"_links":{"self":[{"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/posts\/73990","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/users\/23"}],"replies":[{"embeddable":true,"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/comments?post=73990"}],"version-history":[{"count":7,"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/posts\/73990\/revisions"}],"predecessor-version":[{"id":73998,"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/posts\/73990\/revisions\/73998"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/media\/73991"}],"wp:attachment":[{"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/media?parent=73990"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/categories?post=73990"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/colombiainteligente.org\/es_co\/wp-json\/wp\/v2\/tags?post=73990"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}